MultiRope MultiRope 300 Relay

Only a few minutes are needed to install the MultiRope sensors: The installation only requires the screws of the retaining strap to be loosened and the sensor to be put against the rope. The retaining strap is then closed again and the screws are tightened up until the rope is pressed against the sensor body. A specifi c tightening torque must not be applied. No special tools are required. Thanks to the integrated evaluation unit no additional cables are needed to connect the sensor and evaluation unit. The unit can be confi gured using three keys and the 4-digit LED display. The unit is connected to the control system by means of 3 freely programmable alarm relays. After the MultiRope sensor has been calibrated, the evaluation unit displays the lift car load. As soon as the parameters for the 3 output relays are entered using the built-in keys the unit is ready for operation.