Escalator Analysis According to ISO18738-2

The various components of the escalator are measured in both directions of movement, unless it is an installation that is actually operated in one direction only. In this case it is sufficient to measure in one direction of movement only.
Measurement of the Load Carrying Units / Steps


With a horizontal moving walk, the measurement can be started immediately. With an escalator or and inclined moving walk, the measurement may only be started at the beginning of the inclination.
With horizontal escalators, the measurement is stopped immediately in front of the step inlet. In case of moving walks or escalators, a measurement is finished immediately in front of the end of the inclination.
Measurement of the Handrails

The positioning of the QS3 sensor should be carried out according to the illustration.
Sound Measurement
The sound level measurement describes the sound aspect of the drive quality as perceived by the passenger.
The sound level measured during this process is the sum of
The sound level measured during this process is the sum of
- the escalator’s sound emission
- the background noise
- the acoustic characteristics of the room in which the escalator is installed
- and the acoustic reflection of the surfaces in the area surrounding the escalator
ISO 18738-2 therefore describes several methods to compensate the effects of background noise and the acoustic behavior of the installation’s location.
Documentation
The software Henning sensor suite creates a complete report according to ISO18738 Part. 2 from the measurements.
This can then be identified as detailed quality certificate of the escalator and traceable archived in due course.
This can then be identified as detailed quality certificate of the escalator and traceable archived in due course.


Extended Evaluations